Home/ Medical, Healthcare Products
Fetal / Maternal Monitor (Venus)
MCF21-Venus Series monitor includes Fetal Monitor and Maternal/Fetal Monitor which is designed for the antepartum,intrapartum and postpartum applications. Feature:
1. 12.1'' color TFT screen, supporting external CRT(Optional) ;
2. Variety of functions:from basic fetal monitoring to integrated maternal/fetal monitoring ;
3. Monitoring fetal parameters:FHR,UA,FM.
4. Monitoring maternal parameters:ECG,SPO2,NIBP,RESP,TEMP,PR ;
5. Optional accessory;built-in thermal recorder ;
6. Built-in network capability ,supporting 8-255 network ;
7. Storing up to 48 hours monitoring data and all data can be recalled;
8. Suitale for monitoring adult,pediatric and neonatal patient ;
9. Reliable high sensibive 12-element doppler transducer .
Physical specification
Size and Weight
Size 380mm * 270mm * 96mm
Weight 4.0 (kg)
Classification
Compatible with GB9706 standard
Environment:
Temperature:
Working 5-40ºC; (41-104ºF)
Storage -20-60ºC ( -4-140ºF)
Humanity:
Working 5-80 %
Storage 5-95 %
Power Supply:
Input: 220V±22V AC, 50HZ±1HZ
Battery
Rechargeable 12NiMH 1 (hrs) Maximum
Capacity: 12V 3 Amp-Hr
Medical Software
Display: 12.1 inch color TFT, 800 × 600 resolution
Language: English/Chinese
Parameter feature
FHR
Transducer: 12 crystals, Pulsed Doppler
Working frequency: 1 MHz
Measurement range: 50-210 bpm
Accuracy: ±2bpm
Alarm range: High: 160,170,180,190 bpm,
Low: 100,110,120 bpm
TOCO
Measurement range: 0-100 units
Accuracy: ±8%
ECG
Leads: I, II, III, aVR, aVL, avF, Vx
Gain: ×0.25, ×1, ×2
HR scope: 30-250 bpm
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
NBP
Method: Oscillometric
Mode: Manual, or Auto
Unit: mmHg, kPa
Measuring scope
SYS: 60-240 mmHg
DIA: 40-200 mmHg
MEAN: 30-180 mmHg
SpO2/PR
SpO2 scope: 70%-100%
Accuracy: ±4%
Pulse scope: 30-250
Resolution: 12bpm
Temperature
Unit: ºC, ºF
Resolution: 0.1 ºC
Accuracy: 0.5ºC
Scope: 26-45ºC
Respiration
Method: Impedance between RA-LL
Resp. rate: 15-99 rpm
Resolution: 1 (rpm)
Accuracy: 10 (rpm)
Recorder(optional)
Paper width: 48 mm
Speed: 25/50 mm/s
Wave channel: 2 channel
| Member Information | |
| Sold by: | Cheer Zhu |
| Phone: | 0086-755-26411741*8615 |
| Your address: | China |
| Company name: | Shenzhen |
| Location: | China |
| : | Offer_to_sell |
| No. | Offers from same user | Added | Location | Pic. |
| 1 | Thermal Printer Unit (76 hits) | 19.12 | China | No |
| 2 | Thermal Printer (74 hits) | 19.12 | China | No |
| 3 | Hand-held Pulse Oximeter (74 hits) | 18.12 | China | No |
| No. | Offers from same catergory | Added | Location | Pic. |
| 1 | Table Top Pulse Oximeter (69 hits) | 18.12 | China | No |
| 2 | E-Monitor (79 hits) | 18.12 | China | No |
| 3 | Competitive hospital ultrasound scanner CX9000E (75 hits) | 18.12 | China | No |