Thermal mass flow sensor


Thermal mass flow sensor picture Thermal gas mass flow meter is designed on the basis of thermal dispersion, and adopts method of
constant differential temperature to measuring gas flow. It has advantages of small size, easy installation,
high reliability and high accuracy, etc.
The meter contains two platinum resistance temperature sensors. The thermal principle operates by
monitoring the cooling effect of a gas stream as it passes over a heated sensor. Gas flowing through the
sensing section passes over two sensors one of which is used conventionally as a temperature sensor,
whilst the other is used as a heater. The temperature sensor monitors the actual process values whilst
the heater is maintained at a constant differential temperature above this by varying the power consumed
by the sensor. The greater the gas velocity, the greater the cooling effect and power required to maintain
the differential temperature. The measured heater power is therefore a measure of the gas mass flow
rate.
The format of gas velocity and power is shown as below:
……(1)
Where: is specific gravity of medium
V is velocity
K is balance coefficient
Q is heater power
Δ T is differential temperature
The medium temperature range of meter is -40℃~220℃.
In the format (1), the specific gravity of medium is related to the density:
……(2)
Where: is the medium density in working condition(kg/m3)
ρn is the medium density in standard condition, 101.325kPa and 20℃ (kg/m3)
P is the pressure in working condition(kPa)
T is the temperature in working condition (℃)
In the formats (1) and (2), there is a certain functional relationship between the velocity and pressure in
working condition, medium density, the temperature in working condition.
Due to the sensor temperature is always 30℃ higher than the medium temperature (environment
temperature), and the meter adopts method of constant differential temperature, therefore the meter do
not need to do temperature and pressure compensation in principle
date Added (m.d.y): 08.22.2018 viewed Offer viewed: 586 (hits)
Member Information
 
Contact person:
Michael Sun
Phone:
+86 17640305359
Location:
China
Type of offer:
Sell
related trade leads  Offers by this member Same catergory  print Print this Page


Click here to contact this member

Related trade leads
Offers from same user
pic. Probe Specifications Convex probe- Adult abdomen application Frequency: 2.5, 3, 3.5, 4, H4, H5MHz Power:5-100% (arithmetic progression ...
2.Paperless recorder KT800 (788 hits)China No
pic. Unlike conventional record that record data on charts, the Instrument displays the measured data acquired in the internal memory to a LCD in the form ...
No. Offers from same catergory
pic. Hello We are the most comprehensive stock inventor we supply titanium Plate /bar We have Bar GR1 GR2 GR4 GR5 GR7 GR9 GR12 the Size from Dia:2mm~100mm Length can be determined ...
2.Nitrogen Storage Vessel (661 hits)China
pic. [url]http://www.dfctank.com[/url]China Nitrogen [b]Storage Vessel Manufacturer[/b] Supplies Carbon Steel Nitrogen Storage Vessel Tank, Bulk Nitrogen (N2) Storage, GB150, 13208 ...
pic. [url]http://www.dfctank.com[/url]China Shell and Tube [b]Heat Exchanger Manufacturer[/b] Provides Stainless Steel Shell and Tube Heat Exchanger, Floating Head, 6.4 Mpa, Up to ...
Import and Export

About us :: Terms & Conditions :: Privacy Policy :: Contact us

Copyright ©2025 Bizviet.Net. All rights reserved.