Vietnam b2b marketplace
Ghost Buster Column The perfect replacemen for the Shimadzu
Home  :: New Trade offers  :: Top Trade offers  :: Sign up! ::Login!
Vietnam photos
Home > Testing Measuring Equipment >

Ghost Buster Column The perfect replacemen for the Shimadzu


[url]https://keenfinebiotech.com/product/ghost-rid-off-column/
Ghost rid-off Column impurity trapping column
Impurity trapping column can effectively remove impurities in mobile phase and completely eliminate ghost peaks, thus greatly shortening the time of method verification and analysis of trace and trace substances.

Especially for drug analysis and research personnel, the Ghost rid-off Column impurity trapping column is your essential artifact to eliminate ghost peaks.

Installation method:
The ghost peak removal column is stored in pure methanol. Before use, it should be washed with pure methanol at a flow rate of 1.0ml/min for 20 minutes. (Note: do not connect the chromatographic column and detector for washing) After washing, remove the column, and connect it between the mixer and the sampler according to the installation position shown above.

The main feature of Ghost rid-off Column impurity trapping column is that it can remove impurities from solvents, including organic solvents. In the gradient analysis of reversed-phase chromatography, installing a small column between the gradient mixer and the automatic sampler can not only remove impurities in the mobile phase, but also effectively remove impurities in the pipeline and mixer.
Service life:
After 600 analyses, there is still no ghost peak. The experimental results show that the trapping column can stably adsorb impurities and has sufficient loading capacity for multiple analyses.

Description:
The actual service life of the product varies according to the analysis conditions, such as the different mobile phases used, and not all impurities can be removed.
After the product is connected to the junction of gradient mixer or pump, there will be a delay volume equal to the column volume in gradient analysis, and almost all brands of liquid instruments can use this product.
When mass spectrometry is used as a detector, the product may be slightly dissolved and cause baseline noise. If the ion pair reagent is used in the analysis, the product may adsorb the ion pair reagent and affect the retention time or peak type of the components.
Before connecting the analytical column, be sure to thoroughly flush the pipeline connecting the product with mobile phase (close to the final concentration in gradient analysis).

Item number (P/N) describe Pressure-resistant/adaptive instrument Column volume
100001-001 Keenfine® Ghost rid-off columnI 50×4.6mm 400 Bar/HPLC 630μL
100002-001 Keenfine® Ghost rid-off columnII 50×4.6mm 400 Bar/HPLC 630μL
100001-002 Keenfine® Ghost rid-off columnI 50×4.0mm 400 Bar/HPLC 480μL
100002-002 Keenfine® Ghost rid-off columnII 50×4.0mm 400 Bar/HPLC 480μL
100002-003 Keenfine® Ghost rid-off columnII 30×4.0mm 400 Bar/HPLC 280μL
100002-004 Keenfine® Ghost rid-off columnII 50×2.1mm 1000 Bar/UHPLC 130μL
100002-005 Keenfine® Ghost rid-off columnII 30×2.1mm 1000 Bar/UHPLC 80μL
Contact information
Manufacturer: Guangzhou Qifeng Biotechnology Co., Ltd.
Sales, after-sales and technical support +86-1805424208,Telegram:@keenfinebiotech;email:Sales@keenfinebiotech.com
Welcome to contact and try to buy.
date Added (m.d.y): 01.11.2025 viewed Offer viewed: 409 (hits)
Member Information
 
Contact person:
Cui zhaoyuan
Phone:
13021721781
Location:
China
Type of offer:
Sell
related trade leads  Offers by this member Same catergory  print Print this Page


Click here to contact this member

Related trade leads
No. Offers from same catergory
pic. PWP350 pressure transmitter/transducer applies high quality Germany imported piezoresistive pressure sensor chip with a fully welded stainless steel housing. Equipped with 3 ...
2.Liquid Turbine Flow Meter (310 hits)China No
pic. PWF-LTF series turbine flow meter is a precision flow measuring instrument that measures the flow and total volume of impurity-free and non-corrosive liquids. It is widely used in ...
3.Electromagnetic flowmeter (239 hits)China No
pic. The electromagnetic flowmeter is used to measure the flow of conductive liquids and slurries as low as 5 Micro Siemens (including corrosive and abrasive) in closed ...
Import and Export

About us :: Terms & Conditions :: Privacy Policy :: Contact us

Copyright ©2025 Bizviet.Net. All rights reserved.